Leak load from the compressors themselves
When production stops, compressor power is mostly feeding leaks. Pulsenode C measures it in every quiet period, so leak load becomes a number you see every week.
Example engagement
This representative distribution center's compressors never quite rest, even when the sorter is still. An ultrasound survey, permanent leak monitors and metered compressors would find where the air goes, and keep finding it.
Example engagement — a representative scenario built from typical deployment parameters. Figures are modeled, not reported results from a named client.
Modeled results
less compressed-air energy (modeled)
compressors able to stay in standby (modeled)
dock doors with open time measured per shift
The situation
Picture a 420,000 sq ft regional distribution center: 80 dock doors, a conveyor and sortation system with pneumatic diverters, case erectors and sealers in pack-out, and three rotary-screw compressors in a room at the back. Two run at fixed speed; the third has a variable-speed drive and trims.
Compressed air is the utility nobody watches. The air is invisible, leaks hiss below the noise of the building, and the cost disappears into a single electric bill. Between waves and on Sunday mornings, with every conveyor stopped, the compressors still load and unload. That is air leaving somewhere other than through a tool.
The dock is the building's other open valve. A door left up between trailers in January lets heated air out as fast as the unit heaters can make it; in August it lets humid air in. Nobody leaves doors open on purpose, and nobody can see which ones stay open.
Constraints
Approach
For a building, the Sprint is a desk study and a walk: a year of utility bills, compressor nameplates and controls, a sketch of the air headers, and an afternoon with a Pulsenode U and temporary power metering. Exit: a go, with a modeled saving and the conditions it depends on, chiefly that leaks found get fixed.
Pulsenode C on all three compressors logs power and load cycles around the clock, so every quiet period becomes a leak-load measurement. A Perflens technician walks the first ultrasound route with site staff, tagging each leak with location, photo and estimated loss. Success criteria, agreed in writing: a measured baseline leak load and a tagged leak list ready to repair from.
Twelve permanent Pulsenode U monitors go on the leak-prone zones the survey found, such as sorter air headers, filter-regulator stations and drop legs at pack-out. Pulsenode C goes on 14 rooftop units, and door signals come from the existing dock control panels. Everything is installed and accepted before the peak-season freeze.
Site technicians repeat the survey route quarterly with the same Pulsenode U. Perflens Care Essentials watches node health, and the monthly report puts leak load, door open time and rooftop-unit faults on one page.
What the system does
When production stops, compressor power is mostly feeding leaks. Pulsenode C measures it in every quiet period, so leak load becomes a number you see every week.
Escaping air makes turbulent ultrasound well above human hearing. A Pulsenode U survey locates leaks by direction and intensity, even overhead.
Fixed monitors on leak-prone zones learn each zone's quiet-period baseline and flag a rise, whether a new leak or an old one that has grown.
Every tagged leak gets a photo, location, estimated loss and a CMMS work order, and stays open until a recheck confirms the repair.
Open time per door per shift, and the doors left open with no trailer restrained, matched against zone temperature and heater runtime.
Current signatures from Pulsenode C show short-cycling compressors, failed fans and units running flat out against an open dock.
Modeled results
less compressed-air energy
compressors able to stay in standby as demand falls
leak-load reading from compressor power, instead of a one-off audit
Modeled for a building of this size with three rotary-screw compressors, two shifts and air used mainly by sortation and pack-out. The baseline leak load is the compressor power drawn during quiet periods, typical of systems with no leak program. Assumes tagged leaks are repaired within a month, the route is resurveyed quarterly and header pressure is reviewed once leaks are under control. HVAC and dock-door effects depend heavily on climate and are reported, not included.
Phase two
Related services
Sub-metering, compressed-air leak detection, HVAC and refrigeration health, and environmental monitoring for whole buildings.
Read more
Vibration and ultrasound monitoring that keeps compressors, conveyors and fans out of the emergency queue.
Read more
Energy, equipment and parcel monitoring for distribution centers that run lean and ship daily.
Read moreFAQ
You can, and it will find leaks. The trouble is afterward. Leaks return as fittings wear and lines get moved, and nobody notices until the bill creeps up. Metered compressors and permanent monitors show when leak load returns, so the next survey is triggered by data rather than the calendar.
No. The gateways sit on their own network segment with no internet connection, and dock signals come through separate remote I/O. The peak-season freeze still applies to physical work on the sorter air headers, which is why installation finished before it.
Rough, and we say so. Ultrasound intensity depends on distance, angle and the shape of the leak, so a per-leak loss estimate is good for ranking repairs, not for billing. The compressor power measurement is the number that counts, because it shows the total leak load before and after repairs.
Send a year of utility bills and your compressor nameplates. On a discovery call we'll tell you whether a survey, permanent monitoring or both are worth doing.